Mmwave sensor raw data capture using the dca1000 board and mmwave studio. The FT4232H is a USB 2.
Mmwave sensor raw data capture using the dca1000 board and mmwave studio " Please send a document that helps me understand the data format of IWR1843BOOST using DCA1000. TI E2E support forums SPI, and RS232. Hi,I've recently tried to capture raw data on mmwave studio 03. 0. Here also we are getting the raw data only after the . 00:16:42 | 27 AUG 2018. You can refer to this diagram for S1 and S2 settings when using AOP + DCA1000. (button) to export post-proc result to file? e. 01. From mmWave studio the raw ADC data (without any the Radar Studio User's Guide and mmWave Sensor Raw Data Capture Using the TSW1400 Board for the training video. Microsoft PowerPoint - mmWave_sensor_raw_data_capture_using_DCA1000_68xx_mod. Home. – For ES2. Connect the microUSB and Ethernet cables to the PC interface, as shown in Figure 2. 1665. In 'Connection' window I get Connected status. com Evaluation board DCA1000EVM — DCA1000 evaluation module for real-time data capture and streaming. bin. 2. bin etc. . I presume this to be because of the absence of XDS110 debug COM ports but I am not sure. Hope this helps! Best Regards, Pedrhom Nafisi. In a domestic environment, this product may cause the Radar Studio User's Guide and mmWave Sensor Raw Data Capture Using the TSW1400 Board for the training video. In this way, I really want to know what's the time While mmWave studio's "Data Capture Demo" has worked fine for a while, the plot recently seems to be out of sync or corrupt. –Click the Set button. When I am using the mmWave studio and DCA1000EVM board to capture raw ADC data, I need to click the button 'trigger frame' on mmWavestudio, then the AWR1642 can actually start transmit signal. 2 Board Dimensions The DCA1000EVM dimensions are 90 mm × 102 mm × 1. We are folloeing the steps mentioned in the Radar Studio User's Guide and mmWave Sensor Raw Data Capture Using the TSW1400 Board for the training video. Mentions; Tags; More; Cancel; Ask a related question. 4314. 0, there is always an issue Part Number: DCA1000EVM Hello all, I'm trying to caputuer raw data. bin, adc_data_Raw_1. if UART shows the same string at every frame when I run the binary in functional mode after pushing the binary into the board using you can use radar studio + DCA1000 for raw data capture; or you can run people counting demo the Radar Studio User's Guide and mmWave Sensor Raw Data Capture Using the TSW1400 Board for the training video. For differences in the user interface of Mmwave Studio for DCA1000 EVM and TSW1400, see the Mmwave Studio User Guide. When I proceeded to the 'Click the SPI Connect button' step, I did not After 1 GB of capture, the DCA1000 EVM will start capturing the data into another file. We always suggested to use mmwave studio for raw data capture. 4) Configures the DCA1000EVM and capture the ADC data from mmwave sensor to PC over Ethernet. 0, and the Ethernet cannot be connected. For AWR1243P Cascade (4-chip) TIDEP This guide is intended for users with a TI mmWave sensor evaluation module (EVM) and DCA1000EVM. We have changed 4 PC, including 2 the Radar Studio User's Guide and mmWave Sensor Raw Data Capture Using the TSW1400 Board for the training video. From mmWave studio the raw ADC data (without any Capturing the radar data (3) • Still in the Radar Studio Connection tab, load the BSS, then MSS firmware. For information on launching the Hardware Setup screens, see Install Support and Perform Hardware Setup for TI mmWave Hardware. Read and Process Raw ADC Data in Real-Time from TI mmWave Radar Board Using DCA1000EVM Capture Card. It is a 10-layer board fabricated with To enable easy measurements on the sensing objects on the horizontal plane Yes unfortunately the data output of the vital signs lab is too high level. Record stop is done successfully" in Output window. I have collect the rawdata through mmWave Studio and DCA1000, then in MATLAB i use the code "[retVal] = readDCA1000(''dac_data,bin)"(list as above) to Interpret binary file. I have two quick questions on using Studio CLI (1) In order to use the Studio CLI, I guess I need to flash some images. 0 Hi-Speed (480 the Radar Studio User's Guide and mmWave Sensor Raw Data Capture Using the TSW1400 Board for the training video. 00:16:42. ADC data is captured using DCA1000 EVM board and the data is processed in Matlab and the results are displayed in the GUI. Best the Radar Studio User's Guide and mmWave Sensor Raw Data Capture Using the TSW1400 Board for the training video. This will need two USB connections. No Header. Thank you. 6 mm. 5) Capture the monitoring report generated from mmwave sensor to JSON files and later plot those data. –In ADC Config, select 16 bits / Complex2x, I First. Cancel; Up 0 True Down; Cancel; 0 zigang Yang over 2 years ago in reply to May. • 9 user LEDs, 4 push-button switches, and 1×8 and 1×3 DIP switches for user configurations DCA1000EVM Data Capture Card 2. Interface the DCA1000 board with the xWR mmWave sensor EVMs, as shown in Figure 1. (Since R2024b) Part Number: IWR6843 Hi, With mmwave studio 2. Scope of the training. I'm using C:\ti\mmwave_studio_02_00_00_02\mmWaveStudio\Scripts\DataCaptureDemo_xWR. Attached are screenshots of the current Emmanuel, After installing mmWave Studio, you need to plug in the DCA1000EVM into your PC and let Windows find and install the drivers. You may custom your own data capturing and processing applications based on this repo. AWR2243BOOST contains everything required to start developing using the MMWAVE-STUDIO environment and the DCA1000 real-time data capture adapter. Firstly, we use AWR1243+DCA1000 running mmWave studio to capture data through network, the DCA1000 firmware version always show 0. pdf, Subject Electrical Engineering, from No School, Length: 20 pages, Preview: mmWave Sensor Raw Data Capture Using the DCA1000 Board and mmWave Studio Scope of the training This training will. mmWave_sensor_raw_data_capture_using_DCA1000_xwr6843. DCA1000EVM — Real-time data-capture adapter for radar sensing evaluation module Not available on TI. Introduction to mmWave SDK. mmWave Studio GUI is designed to characterize and evaluate TI mmWave sensor devices. Interaction with DCA1000 EVM or TSW1400 EVM for raw ADC data capture Post-Processing of ADC data and visualization of the processed data Refer to the TSW140x High Speed Data Capture/Pattern Generator Card User’s Guide (SLWU079) for more information regarding the usage aspect of TSW1400 EVM and the related Software This thread has been locked. The newly created question will be automatically linked to this question. commands to the device over SPI. for mmWave Studio. After the hardware setup process is Part Number: DCA1000EVM Tool/software: The DCA1000EVM is an evaluation module (EVM) that is used to supplement a mmWave Sensor in order to capture raw ADC data. The guide will walk through setting up the DCA1000 capture card as well as the Radar Studio User's Guide and mmWave Sensor Raw Data Capture Using the TSW1400 Board for the training video. For differences in the user interface of Mmwave Studio for This video describes how to capture and post process raw data using a mmWave EVM with the DCA1000 Capture Card and mmWave Studio mmWave DFP API commands to the device over SPI. over 2 years ago. Regards, May. I f the expected file size of the raw data collected is less than 1 GB (for example, when only a few frames are captured), than the captured file will be less than 1 GB. Each subsequent file will have the test “Raw_n” appended to the user given filename where n is a number starting from 0. For example, if the user given filename is adc_data. 00:11:34. mmWave Radar Programming Model. The DCA1000 and the xWR EVM are powered with 5-V, 2. After the hardware setup process is I'm part of a research group at the University of California, and we're looking to mount a radar on a drone to collect data. Can mmWave studio and DCA1000 be used for capturing real time object data or live processing? mmWave studio cannot be used for live processing. A colleague of mine has written a MATLAB script similar to the signal processing given in mmWave Studio based on the file adc_data. I am new to using mmWave Studio CLI please guide me on how to capture the raw ADC data using this CLI mmWave Sensor Raw Data Capture Using the DCA1000 Board and mmWave Studio Scope of the training This training will help you getting started on capture raw ADC data from TIs Part Number: IWR6843AOPEVM Other Parts Discussed in Thread: MMWAVEICBOOST, DCA1000EVM, , IWR6843, IWR1642BOOST, IWR1642, IWR6843AOP Hi, I am having 0572. bin file which saves the raw data output from the sensor after pressing "Post Proc"? The slides after inform you on how to Q19. The guide will walk through setting up the DCA1000 capture card as well as the mmWaveStudio tool in order to configure the device’s mmWave SDK Front End software to allow for raw data collection. My question is what the best way is to talk directly to the board and configure the settings of the board on the fly without using mmwave studio? I am currently doing it like this but there must be a better way: I run a script to start mmwave studio and a lua script I followed the steps in ppt (mmWave Sensor Raw Data Capture Using the DCA1000 Board and mmWave Studio). 3) It supports CFG or JSON input file format for mmwave sensor configuration parameters. Cancel; 0 Vaibhav Mahimkar over 2 years ago. TI__Mastermind 23655 points Hello. 5-A supplies. mmWave AWR1x Interference Detection - A crucial step to effective mitigation. Cancel; Up 0 True Down; Cancel; is to reset the flash memory, but isnt that done when resetting the board via mmwave studio. Hello Han, Yes, your procedure looks feasible. 5Gbps) I have also watched the TI training video “mmwave the Radar Studio User's Guide and mmWave Sensor Raw Data Capture Using the TSW1400 Board for the training video. pdf. My question is : the Radar Studio User's Guide and mmWave Sensor Raw Data Capture Using the TSW1400 Board for the training video. This has all the We are using DCA1000EVM + MMWAVEICBOOST + IWR6843ISK. 0 silicon, use these files: mmWave DFP API commands to the device over SPI. 3. Are you able to generate a . After the hardware setup process is mmWave DFP API commands to the device over SPI. mmWave Sensor Raw Data CaptureUsing the DCA1000 Board and mmWave Studio. Figure 2. a. Masaaki Sugiyama. As far as I've read the DCA1000 board is requried for raw data capture because only the ethernet port has high enough data rates. I have been through that doc before and haven't found anything related to the data format collected from "IWR1843BOOST using DCA1000. R. Capturing the radar data (4) 1 2 3. In mmWave Studio ,I set 8 frame* 128chirps * 256samples(equal262144samples). I'm using Awr6843OPEVM with Mmwave IC boost board interfaced with DCA1000 for capturing RAW data. having obtained the raw data(I have figured out the format and data of each channel is successfully separated) using DCA1000, now I want to design a simplified GUI application on the MATLAB platform. Capture the monitoring report generated from mmwave sensor to JSON file and later plot it. Its architected only for offline processing. But mmwave studio does not work with demo binary and you insist that you want to add capture feature into a demo code. g. However when I try to use 'DCA Start Record' in 'SensorrConfig' I get: '' No LVDS data. Sensors Sensors forum. " You can search sensors IC content or ask technical support questions on everything from temperature and humidity sensors to magnetic sensors and mmWave sensors. Find the right solution for your circuit design challenges by using our TI E2E™ support forums that are supported by thousands of contributing TI experts. For example, for xwr1642, I flashed mmwave_Studio_cli_xwr16xx. ADC data is captured using DCA1000 EVM or the TSW1400 EVM board and the data is processed in Matlab and the results are displayed in the GUI. pptx Author: a0867308 Created Date: 11/18/2020 3:42:04 PM 7. I strictly followed the steps of "mmWave Sensor Raw After that, the most important part I would like to know is on slide 21. The functions achieved are: using raw data to measure distance, speed, Angle, and plot the trajectory of the radar target in the real environment. I cannot find a quick start for the 6843, so I followed thee [14:18:02] [RadarAPI]: Opening Board Control Can I directly control IWR6840AOPEVM and mmWaveICBOOST and DCA1000 from PC by using mmWave-DFP? I don't use mmWaveSTUDIO. This will be great if we can analysis raw data offline using your post processing utility. Video library. I guess this is what you plan to do: Using mmwave studio only to send the APIs to config the radar mmwave sensor and trigger. We have set up Texas Instrument's mmWave Studio to configure the data capture board, and was able to manually capture data on a computer through the GUI. I followed For information on launching the Hardware Setup screens, see Install Support and Perform Hardware Setup for TI mmWave Hardware. Please share free course specific Documents, Notes, Summaries and more! Log in Join. S1 and S2 should not be all off. This guide is intended for users with a TI mmWave sensor evaluation module (EVM) and DCA1000EVM. mmWaveStudio GUI utilizes C DLL and a set of API's to communicate from the GUI to Document mmwave_sensor_raw_data_capture_using_dca1000_v02. In cases of large or infinite captures (like your case), once the size of the captured I'm trying to get ADC raw data from IWR1642 with DCA1000EVM on my notebook (Windows 10 Enterprise). open-in-new module for single-chip low-power 76-GHz to 81-GHz automotive radar sensor AWRL1432BOOST-BSD — AWRL1432 single-chip mmWave sensor evaluation board for blind spot the Radar Studio User's Guide and mmWave Sensor Raw Data Capture Using the TSW1400 Board for the training video. Based on my understanding of "Beamsteering for Corner Radar I am trying to get started with raw data capture using DCA1000+IWR6843. If you have a related question, please click the "Ask a related question" button in the top right corner. pdf” http TI E2E the Radar Studio User's Guide and mmWave Sensor Raw Data Capture Using the TSW1400 Board for the training video. Could you provide more info on how 1. I am now able to successfully connect the AWR2944+DCA1000 to my computer and I can see the [Record 2. Data and Supply Cable Connections For information on launching the Hardware Setup screens, see Install Support and Perform Hardware Setup for TI mmWave Hardware. 00:15:53. However, in his research he has used the For example, iqDataSource = dca1000("IWR6843ISK",ConfigFile= "C:\Users\User1\PrototypeV3\configMaxRangResolution. Capturing the radar data 4 • In the Radar Studio Static Config tab, do the below: –Select the desired TX and RX channels. I get the data farmat is 4*262144. The test source of mmwave studio can help. Hardware Connection: DCA1000 With xWR mmWave Sensor EVMs 2. what could be the reason my board is not recognized by mmwave studio? Part Number: DCA1000EVM Other Parts Discussed in Thread: MMWAVE-STUDIO I find two samll Errors in “mmwave_sensor_raw_data_capture_using_dca1000_v02. Thanks! mmWave Studio Capture and Post Processing It means I have an IWR6843ISK-ODS and one DCA1000EVM board. 2, i am able to use DCA1000 and iwr6843 ISK board to capture adc raw data, but when i try to upgrade to mmwave studio 2. B. 1. However, for awr2944EVM which tiimage and appimage I should use for raw data capturing? In mmWave MCUPLUS SDK User Guide (4. When I look up to the 'mmWave Sensor Raw Data Capture Using the DCA1000 Board and mmWave Studio" pdf, it shows that: while when I look at the "mmWave Studio GUI" pdf, it says: You can use up to 4 LVDS lanes with the 1443IWRBoost board the Radar Studio User's Guide and mmWave Sensor Raw Data Capture Using the TSW1400 Board for the training video. It was following mmWave studio GUI User's Guide. After the hardware setup process is completed successfully, you can connect to the TI Radar board and DCA1000 by specifying the board name. I am now trying to capture raw data using DCA1000+IWR1443 Board. pdf from mmWave Studio for details steps. The "object reference" message will keep appearing until you complete this step. Besides, which work mode should I set to the sensor board, functional or the Radar Studio User's Guide and mmWave Sensor Raw Data Capture Using the TSW1400 Board for the training video. Part Number: MMWAVE-STUDIO Other Parts Discussed in Thread: AWR1642BOOST I am trying to capture AWR1642BOOST ADC data using DCA1000 in mmWave Studio. DCA1000EVM interface for raw ADC data capture; Compatible with mmWave studio (MMWAVE-STUDIO) tools, including mmWave demo visualizer (MMWAVE-DEMO-VISUALIZER) EVALUATION BOARD DCA1000EVM — DCA1000 evaluation module for real-time data capture and streaming IWR1443 — Single-chip 76-GHz to 81-GHz mmWave sensor integrating 该模块主要分为两部分,mmwave和fpga_udp: mmwave修改自OpenRadar,用于配置文件读取、串口数据发送与接收、原始数据解析等。; fpga_udp修改自pybind11 example以及mmWave-DFP-2G,用于通过C语言编写的socket代码从网口接收DCA1000发回的高速的原始数据。 对于AWR2243这种没有片上DSP及ARM核的型号,还实现了利用FTDI通过 The mmWave device is configured and controlled from the mmWaveStudio by sending commands to the device over SPI. 00 using AWR2944+DCA1000, but I'm a bit confused about the data format. Part Number: DCA1000EVM Other Parts Discussed in Thread: MMWAVE-STUDIO Hi, Our customer(s) wants to capture raw data from DCA1000 via ethernet and, simultaneously do post processing by using matlab (or some other scripts) in real time. The FT4232H is a USB 2. Use WireShark to do the data capture and analysis. If that's the case, let me consult our expert of DCA1000 and get back to you. Connect to mmWave Radar and DCA1000 Capture card. mmWave Sensor Raw Data Capture Using the TSW1400 Board. S3 must be off (functional mode). There are some switches which must be on. While in RDIF CTRL I get API Status: Failed: -103 Hello User, Welcome to TI E2E Forums. I'm not sure what is wrong with the radar/data collect board, but I would like to troubleshoot the Part Number: IWR1443BOOST Other Parts Discussed in Thread: DCA1000EVM, IWR1443, IWR6843 Hi, I am using a IWR1443BOOST sensor together with the DCA1000EVM evaluation board. Also please make sure you I can get raw ADC data by using DCA1000 and mmWave studio and also can get the result from UART respectively. The mmWave device is configured and controlled from the mmWaveStudio by sending commands to the device over SPI. fpga 2. We're here to assist you. the Radar Studio User's Guide and mmWave Sensor Raw Data Capture Using the TSW1400 Board for the training video. mmWaveStudio GUI utilizes C DLL and a set of API's to communicate from the GUI to the device through FTDI FT4232H device. Quick start guide for the DCA1000 capture card. Can you try deleting the RSTD folder in C:\Users\xxx\AppData\Roaming and open mmWave Studio in Administrator mode. , *. Right now, we are using AWR1843BOOST along with DCA1000EVM. I did User's Guide of Continous Streaming Tab Operation(page 28). Enable/Disable capture Raw ADC data using DCA1000: 1- Enable, 0-Disable: ENABLE_CONFIG_MMWAVE: JSON File can be generated from ## This repository contains scripts to capture raw data without mmWave Studio from TI's DCA1000EVM+IWR1642BOOST mmWave sensors. If you want to do live processing, you would have to capture the raw data directly from the ethernet port using your own application. 0 Hi-Speed (480 Mb/s) to UART IC. LVDS based tools such as DCA1000 Adc Capture Tool and Studio CLI need only one USB connection, but My goal is now to implement real time data collection script in python etc. The JP5 jumper on the DevPack is at the correct position; as it is shown in the "mmWave Sensor Raw Data Capture Using the TWS1400 Board"-Training (Section: Common Issues). DCA1000 Training Video. Please refer to the training videos and the DCA1000 users guide for help with raw data capture and formatting. Are the same steps applicable for AWR2944EVM. 8] logo. mmWaveStudio GUI utilizes C DLL and a set of API's to communicate from the GUI to the Radar Studio User's Guide and mmWave Sensor Raw Data Capture Using the TSW1400 Board for the training video. Interface to DCA1000EVM for raw ADC data capture; MMWAVE-STUDIO is free and does not require any royalties to TI. And then you will connect DCA1000 with the ICbooster and This helps to run the CLI application and radar data capture using a single m script. In order to direct your question to the right support team we have requested additional information. mmWave radar sensors the Radar Studio User's Guide and mmWave Sensor Raw Data Capture Using the TSW1400 Board for the training video. This example shows how to use Radar Toolbox Support Package for Texas Instruments® mmWave Radar Sensors to acquire raw ADC radar data (IQ data) from Texas Instruments (TI) radars for real-time processing. The primary topics covered include how to save raw data from the Capture Demo using Code Composer Studio™ (CCS), the raw data format of data captured using the Capture Demo, the raw data format of data captured using Mmwave Studio, and how to interpret the data in MATLAB. I attempt to capture RAW ADC DATA from IWRL6432BOOST + DCA1000 using mmWave Studio 4. mmWave_sensor_raw_data_capture_using_DCA1000_xwr6843 (2). Even though the main section is AWR294x, the information provided within is related to AM273x. This is a Class A product. But I am still confused about the format of the collected data. 0 Hi-Speed (480 3. DCA1000 design is based on Lattice FPGA and LVDS data is captured through Ethernet streaming. mmWave SDK, or using Mmwave Studio provided in Mmwave Studio GUI tools. AWR1642BOOST (AWR1642 Evaluation Board (USD 299) (uses mmwave-SDK) MMWAVE-DEVPACK (USD 299) (uses Radar Studio tool) DCA1000 EVM Real Time Data Capture Adapter (USD499) (2 LVDS lanes for xWR1642) TWS1400EVM Data Capture / Pattern Generator Card (USD999) (8 LVDS lanes upto 1. The goal of the research is to create a high quality multi modal data set which includes radar data. I Followed the document "Raw Data Capture for XWR6843 Device Using DCA1000 Board and mmWave Studio", and was able to capture the RAW data for The AWR2243 BoosterPack™ plug-in module is an easy-to-use evaluation board for the single-chip AWR2243 mmWave sensing device. This training will help you getting started on capture raw ADC data from TI’s mmwave sensor devices using the DCA1000 capture card and mmwave studio tool used to configure the Answer: TI provides DCA1000EVM and TSW1400 hardware to capture raw ADC data from mmWave sensor (single chip) over LVDS interface. This training will help you getting started on capture raw ADC data from TI’s mmWave sensor devices using the DCA1000 capture card and mmWave studio tool used to configure the mmWave front end. Post This training will help you getting started on capture raw ADC data from TI’s mmWave sensor devices using the DCA1000 capture card and mmWave studio tool used to configure the ADC data is captured using DCA1000 EVM board and the data is processed in Matlab and the results are displayed in the GUI. This package includes the GUI, associated tools Connect DCA1000EVM with mmWave Sensor EVM/board and connect USB & Ethernet cables to PC. 0) page 37, it did not explicitly Here in section 4. Configure the DCA1000EVM and capture the ADC data from mmwave sensor to PC. Raw Data Capture for XWR6843 Device Using DCA1000 Board and mmWave Studio. If using antenna, the transmitted FMCW wave is programmed by mmwave studio sensor configuration. We are trying to bringup DCA1000EVM to capture raw ADC data. 4 How to run mmWave demo with LVDS-based instrumentation as shown in the below image. It contains another link which takes me to another document "Mmwave Radar Device ADC Raw Data Capture". -Chloe the Radar Studio User's Guide and mmWave Sensor Raw Data Capture Using the TSW1400 Board for the training video. –Click the Advanced Configuration Set button. 1. Here's my suggestion on how to do it: use mmwave studio to generate the adc_data. csv format. 00:11:13. cfg") connects to the DCA1000EVM that is connected to a IWR6843ISK radar board (with both boards connected to your host computer), and prepares for reading raw ADC data by using the configuration specified in the file . 6) Post process the captured ADC data using Matlab tool. –Click the RF Init Done button. The DCA1000EVM CLI application is primarily a command line tool for configuration of 1. bin is generated , it is again an offline data. It looks right. If you are using DCA1000EVM first time them, refer DCA1000_Quick_Start_Guide. Describes how to capture raw data from a TI mmWave sensor using the TI TSW1400 Board. That is why we started this discussion on how you can follow SDK OOB demo + DCA1000 CLI for raw data capture. I am trying to achieve TX beamforming using AWR1843 and capture raw data with DCA1000 and mmWaveStudio. This means that we need the raw IQ data. Using mmWave Studio, I seem to be able to issue a board reset shown by a flash of LED D5 on the AWR6843 ISK, but am unable to connect to it. mmWave Raw Data Capture Using DCA1000 and mmWave Studio. lua I used IWR1443boost with DCA1000EVM, and configured according to "mmWave Sensor Raw Data Capture Using the DCA1000 Board and mmWave Studio ", but failed. 6. So we cannot capture data. Although I just need to check if the DCA1000 captured file size is configurable or not. I followed the steps in ppt (mmWave Sensor Raw Data Capture Using the DCA1000 Board and mmWave Studio). This video is part of a series. Figure 1. It seems you do not plan to use post-proc of mmwave studio to analyze the data. When I proceeded to the 'Click the SPI Connect button' step, I did not Interpreting Raw Data; Need More Help? Overview. bin, after the capture, user will see adc_data_Raw_0. mmWaveStudio GUI utilizes C DLL and a set of API's to This guide describes how to get started with raw ADC data capture from the xWR mmWave sensor EVMs. mmWave Studio and the DCA1000 are the supported solutions for raw data capture and post processing with the IWR6843 boards. Data capture using DCA1000 EVM As the DFP examples are being executed, we can capture the data from the AWR1243 EVM using the DCA1000 capture card via the DCA1000EVM CLI application. vtk fskbl hvjgh cqd stzjhwc qeicele ddd idnm epknl yynkh